Shop Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM P/N: 58031404
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM 58031404 Image 1 of 2
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM 58031404
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM 58031404 Image 2 of 2
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM 58031404
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM 58031404
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM 58031404

Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM P/N: 58031404

$820.00

Product Number: 58031404

The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).

2-Electrode Conductivity Sensor

  • One Sensor for an Extensive Measurement Range

    • The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.

  • Superior Measurement Accuracy

    • The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.

  • High Accuracy in Pure Water

    • UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.

  • Highly Stable Digital Signal

    • ISM technology converts the conductivity measurement into a highly stable, robust digital signal which is sent to the transmitter, enabling the sensor to quickly respond to minor changes in conductivity.

  • Fast and Easy Installation

    • ISM's plug-and-measure feature makes sensor installation fast and easy, since all relevant status and configuration information is stored in the sensor and automatically transferred from the sensor to the transmitter during startup.

  • Easy Traceability

    • Identification, calibration and maintenance data is stored in the UniCond sensor, which allows for clear traceability. The sensor meets strict NIST-traceable calibration requirements.

  • For Most Pure and Ultrapure Water Types

    • The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Quantity:
Add To Cart

Product Number: 58031404

The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).

2-Electrode Conductivity Sensor

  • One Sensor for an Extensive Measurement Range

    • The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.

  • Superior Measurement Accuracy

    • The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.

  • High Accuracy in Pure Water

    • UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.

  • Highly Stable Digital Signal

    • ISM technology converts the conductivity measurement into a highly stable, robust digital signal which is sent to the transmitter, enabling the sensor to quickly respond to minor changes in conductivity.

  • Fast and Easy Installation

    • ISM's plug-and-measure feature makes sensor installation fast and easy, since all relevant status and configuration information is stored in the sensor and automatically transferred from the sensor to the transmitter during startup.

  • Easy Traceability

    • Identification, calibration and maintenance data is stored in the UniCond sensor, which allows for clear traceability. The sensor meets strict NIST-traceable calibration requirements.

  • For Most Pure and Ultrapure Water Types

    • The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Conductivity Standard 500ml (58078001, 58078002)
Conductivity Standard 500ml (58078001, 58078002)
from $138.00
Accurate Reference:
Mettler Toledo Conductivity Flow Chamber PVDF P/N:58084001
Mettler Toledo Conductivity Flow Chamber PVDF P/N:58084001
$565.00
Mettler Toledo Flow Housing Large Bore 316 SS P/N: 58084016
Mettler Toledo Flow Housing Large Bore 316 SS P/N: 58084016
$478.00
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
$471.00

Product Number: 58031404

The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).

2-Electrode Conductivity Sensor

  • One Sensor for an Extensive Measurement Range

    • The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.

  • Superior Measurement Accuracy

    • The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.

  • High Accuracy in Pure Water

    • UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.

  • Highly Stable Digital Signal

    • ISM technology converts the conductivity measurement into a highly stable, robust digital signal which is sent to the transmitter, enabling the sensor to quickly respond to minor changes in conductivity.

  • Fast and Easy Installation

    • ISM's plug-and-measure feature makes sensor installation fast and easy, since all relevant status and configuration information is stored in the sensor and automatically transferred from the sensor to the transmitter during startup.

  • Easy Traceability

    • Identification, calibration and maintenance data is stored in the UniCond sensor, which allows for clear traceability. The sensor meets strict NIST-traceable calibration requirements.

  • For Most Pure and Ultrapure Water Types

    • The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

You Might Also Like

Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 2 ISM P/N: 58031407
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 2 ISM P/N: 58031407
$1,050.00
Mettler Toledo pH Sensor Pure Water pHure LE ISM 30039086 Mettler Toledo pH Sensor Pure Water pHure LE ISM 30039086
Mettler Toledo pH Sensor Pure Water pHure LE ISM 30039086
$1,305.00
Mettler Toledo Cond Sensor 1 NPT 4E CPVC/SS ISM P/N: 58031422
Mettler Toledo Cond Sensor 1 NPT 4E CPVC/SS ISM P/N: 58031422
$1,065.00
Mettler Toledo Technical Buffer pH 4.01 250ml 51340057
Mettler Toledo Technical Buffer pH 4.01 250ml 51340057
$105.00
Mettler Toledo Sensor PureWater ISM Optical DO P/N: 30041040
Mettler Toledo Sensor PureWater ISM Optical DO P/N: 30041040
$7,206.00