Shop Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213
Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213 Image 1 of
Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213
Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213

Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213

$665.00

Product Number: 58031213

This analog conductivity sensor is a 2-electrode sensor. Due to its titanium concentric electrodes, this sensor is suitable for measurement in ultra-pure and high-purity water.

2-Electrode Analog Conductivity Sensor

  • Water Measurement in Multiple Industries: The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.

  • Traceable Calibration: Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.

  • Very Fast Response: The titanium electrode of this conductivity sensor makes it more sensitive, so it responds more quickly to measurements.

  • Exceptional Measurement Accuracy: The optimized 4-wire measuring circuitry provides exceptional range and accuracy, eliminating cable effects.

  • Strong Chemical Resistance: Chemical resistance and an optimal response are provided through titanium electrodes, the PTFE-coated stainless steel fitting and the PEEK insulator.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 2,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ½ inch NPT

Cable: 0.5 m (1.5 ft)

Cell Constant (accuracy): ± 1%

Connector: Standard

Electrode Configuration: 2-electrode

Electrode Material: Titanium

Fitting material: Noryl

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 29mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.02 - 2,000 µS/cm

Measurement Technology: Conductive

Model Family: Analog

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ½" NPTM

Sensor Material: Titanium

Quantity:
Add To Cart

Product Number: 58031213

This analog conductivity sensor is a 2-electrode sensor. Due to its titanium concentric electrodes, this sensor is suitable for measurement in ultra-pure and high-purity water.

2-Electrode Analog Conductivity Sensor

  • Water Measurement in Multiple Industries: The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.

  • Traceable Calibration: Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.

  • Very Fast Response: The titanium electrode of this conductivity sensor makes it more sensitive, so it responds more quickly to measurements.

  • Exceptional Measurement Accuracy: The optimized 4-wire measuring circuitry provides exceptional range and accuracy, eliminating cable effects.

  • Strong Chemical Resistance: Chemical resistance and an optimal response are provided through titanium electrodes, the PTFE-coated stainless steel fitting and the PEEK insulator.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 2,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ½ inch NPT

Cable: 0.5 m (1.5 ft)

Cell Constant (accuracy): ± 1%

Connector: Standard

Electrode Configuration: 2-electrode

Electrode Material: Titanium

Fitting material: Noryl

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 29mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.02 - 2,000 µS/cm

Measurement Technology: Conductive

Model Family: Analog

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ½" NPTM

Sensor Material: Titanium

Conductivity Standard 500ml (58078001, 58078002)
Conductivity Standard 500ml (58078001, 58078002)
from $138.00
Accurate Reference:

Product Number: 58031213

This analog conductivity sensor is a 2-electrode sensor. Due to its titanium concentric electrodes, this sensor is suitable for measurement in ultra-pure and high-purity water.

2-Electrode Analog Conductivity Sensor

  • Water Measurement in Multiple Industries: The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.

  • Traceable Calibration: Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.

  • Very Fast Response: The titanium electrode of this conductivity sensor makes it more sensitive, so it responds more quickly to measurements.

  • Exceptional Measurement Accuracy: The optimized 4-wire measuring circuitry provides exceptional range and accuracy, eliminating cable effects.

  • Strong Chemical Resistance: Chemical resistance and an optimal response are provided through titanium electrodes, the PTFE-coated stainless steel fitting and the PEEK insulator.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 2,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ½ inch NPT

Cable: 0.5 m (1.5 ft)

Cell Constant (accuracy): ± 1%

Connector: Standard

Electrode Configuration: 2-electrode

Electrode Material: Titanium

Fitting material: Noryl

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 29mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.02 - 2,000 µS/cm

Measurement Technology: Conductive

Model Family: Analog

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ½" NPTM

Sensor Material: Titanium

You Might Also Like

Mettler Toledo Water Transmitter M800 4 Channels P/N: 58000804
Mettler Toledo Water Transmitter M800 4 Channels P/N: 58000804
$5,495.00
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 2 ISM P/N: 58031407
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 2 ISM P/N: 58031407
$1,050.00
Mettler Toledo Cond Sensor 3/4NPT 0.01C Ti 2 ISM P/N: 58031410
Mettler Toledo Cond Sensor 3/4NPT 0.01C Ti 2 ISM P/N: 58031410
$1,130.00
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408
$1,100.00
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201
$765.00

Analyzer Parts Co

Other Information

8645 S. Harrison St. , Midvale, UT 84070(801) 576-8796
info@samplepanels.com
Analyzer Parts Co Logo

Useful Links

Shop

About

Contact

A division of Solution Sample Systems

Check out Solutions Sample Systems