Shop Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408 Image 1 of
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408

Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 6 ISM P/N: 58031408

$1,100.00

Product Number: 58031408

The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).

2-Electrode Conductivity Sensor

  • One Sensor for an Extensive Measurement Range: The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.

  • Superior Measurement Accuracy: The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.

  • High Accuracy in Pure Water: UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.

  • Highly Stable Digital Signal: ISM technology converts the conductivity measurement into a highly stable, robust digital signal which is sent to the transmitter, enabling the sensor to quickly respond to minor changes in conductivity.

  • Fast and Easy Installation: ISM's plug-and-measure feature makes sensor installation fast and easy, since all relevant status and configuration information is stored in the sensor and automatically transferred from the sensor to the transmitter during startup.

  • Easy Traceability: Identification, calibration and maintenance data is stored in the UniCond sensor, which allows for clear traceability. The sensor meets strict NIST-traceable calibration requirements.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 50,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ¾ inchNPT

Cell Constant (accuracy): ± 1% for 0.02-5,000 µS/cm; ± 3% for > 5,000 µS/cm

Connector: n/a

Electrode Configuration: 2-electrode

Electrode Material: Monel

Fitting material: PTFE/SS

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 132mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.01 - 50,000 µS/cm

Measurement Technology: Conductive

Model Family: UniCond

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ¾" NPTM

Sensor Material: Monel, 316 SS

Quantity:
Add To Cart

Product Number: 58031408

The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).

2-Electrode Conductivity Sensor

  • One Sensor for an Extensive Measurement Range: The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.

  • Superior Measurement Accuracy: The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.

  • High Accuracy in Pure Water: UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.

  • Highly Stable Digital Signal: ISM technology converts the conductivity measurement into a highly stable, robust digital signal which is sent to the transmitter, enabling the sensor to quickly respond to minor changes in conductivity.

  • Fast and Easy Installation: ISM's plug-and-measure feature makes sensor installation fast and easy, since all relevant status and configuration information is stored in the sensor and automatically transferred from the sensor to the transmitter during startup.

  • Easy Traceability: Identification, calibration and maintenance data is stored in the UniCond sensor, which allows for clear traceability. The sensor meets strict NIST-traceable calibration requirements.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 50,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ¾ inchNPT

Cell Constant (accuracy): ± 1% for 0.02-5,000 µS/cm; ± 3% for > 5,000 µS/cm

Connector: n/a

Electrode Configuration: 2-electrode

Electrode Material: Monel

Fitting material: PTFE/SS

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 132mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.01 - 50,000 µS/cm

Measurement Technology: Conductive

Model Family: UniCond

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ¾" NPTM

Sensor Material: Monel, 316 SS

Conductivity Standard 500ml (58078001, 58078002)
Conductivity Standard 500ml (58078001, 58078002)
from $138.00
Accurate Reference:
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
$471.00
Mettler Toledo Conductivity Flow Chamber PVDF P/N:58084001
Mettler Toledo Conductivity Flow Chamber PVDF P/N:58084001
$565.00
Mettler Toledo Flow Housing Large Bore 316 SS P/N: 58084016
Mettler Toledo Flow Housing Large Bore 316 SS P/N: 58084016
$478.00

Product Number: 58031408

The UniCond 2-electrode conductivity sensor provides an exceptionally wide measurement range due to its advanced built-in circuit. The sensor can be used to measure everything from ultrapure water to brackish water (up to 50,000 μS / cm).

2-Electrode Conductivity Sensor

  • One Sensor for an Extensive Measurement Range: The digital UniCond sensor reduces equipment inventory by enabling the measurement of an extensive water purity range with a single sensor model.

  • Superior Measurement Accuracy: The advanced measuring techniques of the UniCond conductivity sensor contribute to superior accuracy over an extended range.

  • High Accuracy in Pure Water: UniCond exceeds performance of conventional sensors due to built-in measuring circuits and analog-to-digital signal conversion in the sensor head.

  • Highly Stable Digital Signal: ISM technology converts the conductivity measurement into a highly stable, robust digital signal which is sent to the transmitter, enabling the sensor to quickly respond to minor changes in conductivity.

  • Fast and Easy Installation: ISM's plug-and-measure feature makes sensor installation fast and easy, since all relevant status and configuration information is stored in the sensor and automatically transferred from the sensor to the transmitter during startup.

  • Easy Traceability: Identification, calibration and maintenance data is stored in the UniCond sensor, which allows for clear traceability. The sensor meets strict NIST-traceable calibration requirements.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 50,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ¾ inchNPT

Cell Constant (accuracy): ± 1% for 0.02-5,000 µS/cm; ± 3% for > 5,000 µS/cm

Connector: n/a

Electrode Configuration: 2-electrode

Electrode Material: Monel

Fitting material: PTFE/SS

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 132mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.01 - 50,000 µS/cm

Measurement Technology: Conductive

Model Family: UniCond

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ¾" NPTM

Sensor Material: Monel, 316 SS

You Might Also Like

Conductivity Standard 500ml (58078001, 58078002)
Conductivity Standard 500ml (58078001, 58078002)
from $138.00
Mettler Toledo Cond Sensor 3/4NPT 0.01C Ti 2 ISM P/N: 58031410
Mettler Toledo Cond Sensor 3/4NPT 0.01C Ti 2 ISM P/N: 58031410
$1,130.00
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
$471.00
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 2 ISM P/N: 58031407
Mettler Toledo Cond Sensor 3/4NPT 0.1C Mnl 2 ISM P/N: 58031407
$1,050.00
Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213
Mettler Toledo Cond Sensor 1/2NPT 0.1C Ti/PPO 2 P/N:58031213