Skip to Content
Analyzer Parts Co
Shop
About
Contact
0
0
Search
Analyzer Parts Co
Shop
About
Contact
0
0
Search
Shop
About
Contact
Search
Shop Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067
Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067 Image 1 of
Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067
Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067

Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067

$2,545.00

Product Number: 52201067

The analog high-performance dissolved oxygen (DO) probe excels in low ppb-level ultrapure water applications. Providing a precise zero and a highly accurate response, the sensor meets the demands of the power and microelectronics industry.

Dependability in Pure Water Applications

  • Control at Low PPB Oxygen Levels: The high-performance DO sensor meets all ultrapure water, low ppb-level measurement challenges in the power and microelectronics industries.

  • Rapid, Accurate Response: The accuracy of the DO sensor allows it to perform well at any level and provide rapid response to changes from one level to another.

  • Tailored to Your Processes: The sensor has been especially designed for power plant cycle chemistry monitoring of ultrapure water in semiconductor and pure water treatment systems.

  • Fast Response with Long-term Stability: With a design that prevents stray oxygen from affecting the measurement signal, the analog high-performance DO probe delivers a very rapid downscale response that helps to ensure the power plant starts up successfully and produces water that is free of defects.

  • Long Life with Exceptional Durability: Combining high performance with a long service life, the analog high-performance DO sensor's gas-permeable, stainless steel, mesh-reinforced PTFE membrane ensures high dependability within demanding low-level ppb applications.

  • Simplified Sensor Maintenance: The maintenance of the in-line DO sensor is simple due to its drop-in modular design. Routine maintenance ensures a reliable sensor performance.

Product Specifications

Accuracy: ± 1% of reading or 1 ppb, whichever is greater; ± 0.5 °C

Measurement Technology: Amperometric/Polarographic

Operating Range: 0 ppb – 10,000 ppb

Flow Rate: 50 mL/min – 1,000 mL/min (0.79 gal/h – 18.85 gal/h)

Measuring Temperature Range: (Celsius)0°C – 60°C for temperature compensation; can tolerate 100°C

Measuring Temperature Range (Fahrenheit): 32°F – 140°F for temperature compensation; can tolerate 212°F

Response Time: 98% in 90 seconds

Preamp: Integral

Intelligent Sensor Management (ISM®): No

Weight: 1 kg (2 lb) with flow housing

Wetted Materials: Polyphenylene sulfide probe body; Polyacetal flow housing; PTFE membrane reinforced with stainless steel and silicone rubber, Viton® and silicone rubber o-rings

Cable Connection: 1/4” NPT(M)

Autoclavable/Sterilizable: No

CableN/AISM (Digital) or Analog: Analog

Material Number: 52201067

Measured Pressure Resistance: 0 bar – 5 bar (0 psig – 72 psig)

Measurement Parameter: Oxygen

Model Family: UPW DO sensors

Primary Media/Application: Semiconductor Water; Pharmaceutical Waters; Power Plant Water/Steam

Sensor Length: 210 mm

Quantity:
Add To Cart

Product Number: 52201067

The analog high-performance dissolved oxygen (DO) probe excels in low ppb-level ultrapure water applications. Providing a precise zero and a highly accurate response, the sensor meets the demands of the power and microelectronics industry.

Dependability in Pure Water Applications

  • Control at Low PPB Oxygen Levels: The high-performance DO sensor meets all ultrapure water, low ppb-level measurement challenges in the power and microelectronics industries.

  • Rapid, Accurate Response: The accuracy of the DO sensor allows it to perform well at any level and provide rapid response to changes from one level to another.

  • Tailored to Your Processes: The sensor has been especially designed for power plant cycle chemistry monitoring of ultrapure water in semiconductor and pure water treatment systems.

  • Fast Response with Long-term Stability: With a design that prevents stray oxygen from affecting the measurement signal, the analog high-performance DO probe delivers a very rapid downscale response that helps to ensure the power plant starts up successfully and produces water that is free of defects.

  • Long Life with Exceptional Durability: Combining high performance with a long service life, the analog high-performance DO sensor's gas-permeable, stainless steel, mesh-reinforced PTFE membrane ensures high dependability within demanding low-level ppb applications.

  • Simplified Sensor Maintenance: The maintenance of the in-line DO sensor is simple due to its drop-in modular design. Routine maintenance ensures a reliable sensor performance.

Product Specifications

Accuracy: ± 1% of reading or 1 ppb, whichever is greater; ± 0.5 °C

Measurement Technology: Amperometric/Polarographic

Operating Range: 0 ppb – 10,000 ppb

Flow Rate: 50 mL/min – 1,000 mL/min (0.79 gal/h – 18.85 gal/h)

Measuring Temperature Range: (Celsius)0°C – 60°C for temperature compensation; can tolerate 100°C

Measuring Temperature Range (Fahrenheit): 32°F – 140°F for temperature compensation; can tolerate 212°F

Response Time: 98% in 90 seconds

Preamp: Integral

Intelligent Sensor Management (ISM®): No

Weight: 1 kg (2 lb) with flow housing

Wetted Materials: Polyphenylene sulfide probe body; Polyacetal flow housing; PTFE membrane reinforced with stainless steel and silicone rubber, Viton® and silicone rubber o-rings

Cable Connection: 1/4” NPT(M)

Autoclavable/Sterilizable: No

CableN/AISM (Digital) or Analog: Analog

Material Number: 52201067

Measured Pressure Resistance: 0 bar – 5 bar (0 psig – 72 psig)

Measurement Parameter: Oxygen

Model Family: UPW DO sensors

Primary Media/Application: Semiconductor Water; Pharmaceutical Waters; Power Plant Water/Steam

Sensor Length: 210 mm

Mettler Toledo Cable DS AK9-RJ12 with Dongle P/N: 52300383
Mettler Toledo Cable DS AK9-RJ12 with Dongle P/N: 52300383
$454.00

Product Number: 52201067

The analog high-performance dissolved oxygen (DO) probe excels in low ppb-level ultrapure water applications. Providing a precise zero and a highly accurate response, the sensor meets the demands of the power and microelectronics industry.

Dependability in Pure Water Applications

  • Control at Low PPB Oxygen Levels: The high-performance DO sensor meets all ultrapure water, low ppb-level measurement challenges in the power and microelectronics industries.

  • Rapid, Accurate Response: The accuracy of the DO sensor allows it to perform well at any level and provide rapid response to changes from one level to another.

  • Tailored to Your Processes: The sensor has been especially designed for power plant cycle chemistry monitoring of ultrapure water in semiconductor and pure water treatment systems.

  • Fast Response with Long-term Stability: With a design that prevents stray oxygen from affecting the measurement signal, the analog high-performance DO probe delivers a very rapid downscale response that helps to ensure the power plant starts up successfully and produces water that is free of defects.

  • Long Life with Exceptional Durability: Combining high performance with a long service life, the analog high-performance DO sensor's gas-permeable, stainless steel, mesh-reinforced PTFE membrane ensures high dependability within demanding low-level ppb applications.

  • Simplified Sensor Maintenance: The maintenance of the in-line DO sensor is simple due to its drop-in modular design. Routine maintenance ensures a reliable sensor performance.

Product Specifications

Accuracy: ± 1% of reading or 1 ppb, whichever is greater; ± 0.5 °C

Measurement Technology: Amperometric/Polarographic

Operating Range: 0 ppb – 10,000 ppb

Flow Rate: 50 mL/min – 1,000 mL/min (0.79 gal/h – 18.85 gal/h)

Measuring Temperature Range: (Celsius)0°C – 60°C for temperature compensation; can tolerate 100°C

Measuring Temperature Range (Fahrenheit): 32°F – 140°F for temperature compensation; can tolerate 212°F

Response Time: 98% in 90 seconds

Preamp: Integral

Intelligent Sensor Management (ISM®): No

Weight: 1 kg (2 lb) with flow housing

Wetted Materials: Polyphenylene sulfide probe body; Polyacetal flow housing; PTFE membrane reinforced with stainless steel and silicone rubber, Viton® and silicone rubber o-rings

Cable Connection: 1/4” NPT(M)

Autoclavable/Sterilizable: No

CableN/AISM (Digital) or Analog: Analog

Material Number: 52201067

Measured Pressure Resistance: 0 bar – 5 bar (0 psig – 72 psig)

Measurement Parameter: Oxygen

Model Family: UPW DO sensors

Primary Media/Application: Semiconductor Water; Pharmaceutical Waters; Power Plant Water/Steam

Sensor Length: 210 mm

You Might Also Like

Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 6 ISM P/N: 58031409
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 6 ISM P/N: 58031409
$895.00
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
Mettler Toledo Conductivity Flow Chamber SS P/N: 58084000
$471.00
Mettler Toledo Reagent Kit Si+PO4 500 mL P/N:30571929
Mettler Toledo Reagent Kit Si+PO4 500 mL P/N:30571929
$750.00
Mettler Toledo Accessory Startup Kit 2300Na P/N:58091233
Mettler Toledo Accessory Startup Kit 2300Na P/N:58091233
$345.00
Mettler Toledo Technical Buffer pH 7.00 250ml 51340059
Mettler Toledo Technical Buffer pH 7.00 250ml 51340059
$105.00

Analyzer Parts Co

Other Information

8645 S. Harrison St. , Midvale, UT 84070(801) 576-8796
info@samplepanels.com
Analyzer Parts Co Logo

Useful Links

Shop

About

Contact

A division of Solution Sample Systems

Check out Solutions Sample Systems