Shop Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201 Image 1 of
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201

Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti/SS 2 P/N: 58031201

$765.00

Product Number: 58031201

This analog conductivity sensor is a 2-electrode sensor. Due to its titanium concentric electrodes, this sensor is suitable for measurement in ultra-pure and high-purity water.

2-Electrode Analog Conductivity Sensor

  • Water Measurement in Multiple Industries: The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.

  • Traceable Calibration: Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.

  • Very Fast Response: The titanium electrode of this conductivity sensor makes it more sensitive, so it responds more quickly to measurements.

  • Exceptional Measurement Accuracy: The optimized 4-wire measuring circuitry provides exceptional range and accuracy, eliminating cable effects.

  • Strong Chemical Resistance: Chemical resistance and an optimal response are provided through titanium electrodes, the PTFE-coated stainless steel fitting and the PEEK insulator.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 2,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ¾ inch NPT

Cable: 0.5 m (1.5 ft)

Cell Constant (accuracy): ± 1%

Connector: Standard

Electrode Configuration: 2-electrode

Electrode Material: Titanium

Fitting material: PTFE/SS

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 34 mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.02 - 2,000 µS/cm

Measurement Technology: Conductive

Model Family: Analog

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ¾" NPTM

Sensor Material: Titanium, 316L SS

Quantity:
Add To Cart

Product Number: 58031201

This analog conductivity sensor is a 2-electrode sensor. Due to its titanium concentric electrodes, this sensor is suitable for measurement in ultra-pure and high-purity water.

2-Electrode Analog Conductivity Sensor

  • Water Measurement in Multiple Industries: The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.

  • Traceable Calibration: Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.

  • Very Fast Response: The titanium electrode of this conductivity sensor makes it more sensitive, so it responds more quickly to measurements.

  • Exceptional Measurement Accuracy: The optimized 4-wire measuring circuitry provides exceptional range and accuracy, eliminating cable effects.

  • Strong Chemical Resistance: Chemical resistance and an optimal response are provided through titanium electrodes, the PTFE-coated stainless steel fitting and the PEEK insulator.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 2,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ¾ inch NPT

Cable: 0.5 m (1.5 ft)

Cell Constant (accuracy): ± 1%

Connector: Standard

Electrode Configuration: 2-electrode

Electrode Material: Titanium

Fitting material: PTFE/SS

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 34 mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.02 - 2,000 µS/cm

Measurement Technology: Conductive

Model Family: Analog

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ¾" NPTM

Sensor Material: Titanium, 316L SS

Conductivity Standard 500ml (58078001, 58078002)
Conductivity Standard 500ml (58078001, 58078002)
from $138.00
Accurate Reference:
Mettler Toledo Conductivity Flow Chamber PVDF P/N:58084001
Mettler Toledo Conductivity Flow Chamber PVDF P/N:58084001
$565.00
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM P/N: 58031404
Mettler Toledo Cond Sensor 3/4NPT 0.1C Ti 2 ISM P/N: 58031404
$820.00

Product Number: 58031201

This analog conductivity sensor is a 2-electrode sensor. Due to its titanium concentric electrodes, this sensor is suitable for measurement in ultra-pure and high-purity water.

2-Electrode Analog Conductivity Sensor

  • Water Measurement in Multiple Industries: The 2-electrode sensor is suitable for pharmaceutical water, power and steam generation, semiconductor water treatment and recycle-and-reclaim water.

  • Traceable Calibration: Sensor accuracy is assured with ASTM and NIST traceable calibration and certification of the cell constant and temperature sensor.

  • Very Fast Response: The titanium electrode of this conductivity sensor makes it more sensitive, so it responds more quickly to measurements.

  • Exceptional Measurement Accuracy: The optimized 4-wire measuring circuitry provides exceptional range and accuracy, eliminating cable effects.

  • Strong Chemical Resistance: Chemical resistance and an optimal response are provided through titanium electrodes, the PTFE-coated stainless steel fitting and the PEEK insulator.

  • For Most Pure and Ultrapure Water Types: The NPTM fitting on the conductivity sensor is designed for most standard conductivity applications. This makes it suitable for the vast majority of pure and ultrapure water applications.

Product Specifications

Operating Range (µS/cm): 0.02 – 2,000

Temperature Sensor: PT 1000

Cell Constant: 0.1 cm-1

Connection: ¾ inch NPT

Cable: 0.5 m (1.5 ft)

Cell Constant (accuracy): ± 1%

Connector: Standard

Electrode Configuration: 2-electrode

Electrode Material: Titanium

Fitting material: PTFE/SS

Hazardous Area Approvals: No

Hygienic/Biocompatibility Approvals: No

Insertion length: 34 mm

Measured Pressure Resistance: 250 psig @ 200 °F

Measured Pressure Resistance: 17 bar @ 93 °C

Measurement Range: 0.02 - 2,000 µS/cm

Measurement Technology: Conductive

Model Family: Analog

Primary Media/Application: Other Water Processes; Semiconductor Water; Other Industrial Processes; Power Plant Water/Steam

Process fitting: ¾" NPTM

Sensor Material: Titanium, 316L SS

You Might Also Like

Mettler Toledo Silica Standard Solution 1L 250 ppb P/N:58078020
Mettler Toledo Silica Standard Solution 1L 250 ppb P/N:58078020
$167.00
Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067
Mettler Toledo DO Sensor UPW Polarographic P/N: 52201067
$2,545.00
Mettler Toledo Thornton Cable ISM 4Wire 10ft 3m P/N: 58080272
Mettler Toledo Thornton Cable ISM 4Wire 10ft 3m P/N: 58080272
$205.00
Mettler Toledo Kit 3000CS Calibration P/N:58091402
Mettler Toledo Kit 3000CS Calibration P/N:58091402
$719.00
Mettler Toledo Water Transmitter M800 4 Channels P/N: 58000804
Mettler Toledo Water Transmitter M800 4 Channels P/N: 58000804
$5,495.00

Analyzer Parts Co

Other Information

8645 S. Harrison St. , Midvale, UT 84070(801) 576-8796
info@samplepanels.com
Analyzer Parts Co Logo

Useful Links

Shop

About

Contact

A division of Solution Sample Systems